page5
Rev.A,03/04
Aircooled2-stroke
FLY dat isalwaysdeliveredwiththefrontplatefor
4-strokeenginesbutwithoutadefinedconfiguration.
Byprogrammingthe,itwillbeadaptedtothe
respectiveenginetype.
FLY dat
2-strokeaircooledengineconfiguration:
CONFIGURATION
18-iFamily®(ISDA)
19-iFamily®(ISCL)
20-Aircraftground
21-Aircraftpower10.0to32.0Volts
22-Memory/Infobutton
23-GroundforPick-Upsensor
24-Pick-Upsensor(4-strokeengines)
25-Pick-Upsensor(2-strokeengines)
1-Thermocouple1(-)
2-Thermocouple1(+)
3-Thermocouple2(-)
4-Thermocouple2(+)
5-Thermocouple3(-)
6-Thermocouple3(+)
7-Thermocouple4(-)
8-Thermocouple4(+)
9-Temperaturesensor1
10-Groundfortemperaturesensor1
-Temperaturesensor2
12-Groundfortemperaturesensor2
13-Oilpressuresensor
14-Groundforoilpressuresensor
15-Powerforoilpressuresensor
16-GroundforALARMunit
17-ALARMoutput
11
Aircraftground
Aircraftpower10.0to32Volts
Memory/Infobutton
Revolutioncounter
signal
00999
Display Designation Unit Resolution
1 Engine speed rpm 1
2 Hours of operation h 0,1
3 Exhaust gas temp. PTO °C or °F 1 or 10
4 Exhaust gas temp. MS °C or °F 1 or 10
5 Cylinder head temp. PTO °C or °F 1
6 Cylinder head temp. MS °C or °F 1
7 empty
8 Ambient air temperature °C or °F 1
Displayandconnection
Wiringdiagram:
white
green
white
green
white
green
white
green
Thermocouple1TypeK
EGT P.T.O.
Thermocouple2TypeK
CHT P.T.O.
Thermocouple3TypeK
EGT M.S.
Thermocouple4TypeK
CHT M.S.
Temperaturesensor2
TypePT100-Ambientairtemperature
ALARMUNIT
(horn,lamp...)
max1Amp
FlydatOperator'smanual
FLYDAT
®
®
DATA
®
S
checK
RPM EGT/PTO CHT/PTO
EGT/MAG CHT/MAG AIRHOURS
1
3 5 7
2
4 6 8